Hysteresisgraph for soft magnet (Dynamic) MATS - 2010M


Automatic measurement of the dynamic magnetic hysteresis loop of oriented and non-oriented silicon steel under the condition of 50 Hz, 60 Hz, 400 Hz and 1 kHz, accurate measurement of the static magnetic characteristic parameters such as amplitude permeability μa, loss angle δ, specific total loss Ps, remanence Br and coercivity Hc. With special testing fixture, it can directly measure the iron core and stator core of the transformer.
Manufacturer: Linkjoin
Bookmark and Share

General Features:

Automatic measurement of the dynamic magnetic hysteresis loop of oriented and non-oriented silicon steel under the condition of 50 Hz, 60 Hz, 400 Hz and 1 kHz, accurate measurement of the static magnetic characteristic parameters such as amplitude permeability μa, loss angle δ, specific total loss Ps, remanence Br and coercivity Hc. With special testing fixture, it can directly measure the iron core and stator core of the transformer.

Windows measurement software applied simply. The product conforms to China National Standards GB/T 3655-2000, GB/T 13789-92 and international standard IEC 404-2, IEC 60404-3, IEC 60404-6.

The controlling of computer and A/D sampling replace the traditional analog bridge, frequency meter, ammeter, voltage meter, power meter, the whole testing process is automatic completed.
 

·Testing sample varieties: hot rolling, cold rolling silicon steel materials, permalloy, amorphous and nm crystal. 

·Testing sample shapes: ribbon and chip open samples, toroid, E and U closing samples. 

·Open circuit samples adopt Epstein Square to form closed magnetic circuit, it can also select permeameter. Closing sample can be put under direct winding measurement, finished transformer can be also put under direct measurement. 

·Sample (iron core), magnetizing coil (N1) and measuring coil (N2) form a no-load transformer. 

·Non-inductive resistance connect to the magnetizing coil loop, and measure the pressure drop of non-inductive resistance to determine the magnetizing current and get the field intensity. The field peak value can be locked through the data feedback, the precision is 0.5%.

·To obtain the field induction intensity through the numeral integral in the voltage of measuring coil. The field peak value can be locked through the data feedback, the precision is 0.5%.

·Power source and sampling amplifier put into a chassis which make the interface very simple: a RS232 interface connect to the computer, the second voltage signal connect to high speed A/D card.

 ·Adopt volammetry and digital integration to measure dynamic hysteresis loop, it can accurately measure dynamic magnetic characteristic parameters such as μa, δ, Ps, Br and Hc, etc. 

·Automatic and continuous measurement up to 255 testing points, the testing time of every testing point is about 30 seconds, fixed-frequency, fixed Bm or fixed Hm optional in multipoint test. 

·Powerful function of the software, the technical request to the testing staff is very low 

Software Screen:

System Specifications

Under 50 Hz frequency, use 25 cm Epstein Square to measure silicon steel sample, technical indices as follows:

Parameters measured Bm (%) Hm (%) μa (%) Ps (%) δ (%)
Uncertainty (k = 2) 1 1 2 1 2
Repeatability (constant temperature) ± 0.5 ± 0.5 ± 1 ± 0.5 ± 1

Instrument Specifications

MATS - 2010M Dynamic Hysteresisgraph   PC6621 A/D Card
    Output Power: 500 VA sine wave
    Frequency Range: 45 Hz ~ 1000 Hz
    Frequency Fineness: 1 Hz
    Frequency Error: < 0.05%
    Output Voltage: 0 ~ 10 V ~ 50 V ~ 150 V ~ 300 V, four automatic ranges
    Voltage Fineness: Program Control 1 mV, panel < 0.1% * current range
    Voltage Distortion Factor: Superior to 0.5%
    Voltage Stability: Superior to 0.02%
    Sampling Current: 2 mA, 5 mA, 10 mA, 20 mA, 40 mA, 80 mA, 200 mA,
    400 mA, 800 mA, 1.6 A, 4 A, 8 A (Peak Value)
    Sample Voltage: 20 mV, 40 mV, 100 mV, 200 mV, 400 mV, 800 mV, 2 V,
    4 V, 8 V, 16 V, 40 V, 80 V, 160 V, 320 V, 800 V, 1600 V (Peak Value)
    Conversion time: <= 2.5 μs (every channel)
    Resolution and Linearity: 12 Bits ± 1 LSB
    Voltage Range: ± 5 V
    Sampling Clock: 5 μs ~ 10 ms Hardware Clock
    Internal Storage Capacity: 4 k Bytes
    Bus Structure: PCI busbar
PC6112 A/D Card
    Conversion time: <= 2.5 μs (every channel)
    Resolution and Linearity: 16 Bits ± 1 LSB
    Voltage Range: ± 5 V ~ ± 10 V
    Sampling Clock: 6 μs ~ 10 ms Hardware Clock
    Internal Storage Capacity: 4 k Bytes
    Bus Structure: PCI busbar
 

Basic Configuration
Serial No. Product Name Model Quantity
1  Test Power Supply  TPS-500M 1
2  Data Acquisition Card  PC6112 1
3  Measurement Software  SMTest 1
4  Computer  lenovo 1
5  Printer  HP1007 laser printer 1
6  Epstein Frame  25 cm 1
7  Square Standard Specimen  About 1 kg 1
 
Remark: above configuration is the reference for customers, final configuration in the contract shall prevail.
Options
Serial No. Options Name Functional Description Remark
1  500 mm × 500 mm SST  Applies to measure half sheet of stalloy  
2  1000 mm × 1000 mm SST  Applies to measure whole sheet of stalloy  
3  Nonstandard Permeameter  Applies to measure stalloy with special size  As required by users

 Software Features:

·Operate under Windows 95/98, Windows 2000/XP operating systems, confirm to Windows software specification, visual and simple operation.

·Full automatic control, intelligent identification, users' interventions are unnecessary in entire testing process.

·Sampling waveform and instrument status under real-time monitoring, and can be stopped at any time.

·The effective sectional area and length of magnetic path of samples can be calculated according to the overall dimension of samples.

·File system adopts database format, can directly print or output test result to Excel form.

·Powerful file management functions: data saving and deleting, remove all the data, etc.

·Data files contain complete sampled data, sample parameters, instrument parameters and testing schemes, adopt text format, can be conveniently typed into other software.

·Display I(t), U(t) and B(t) sampling waveform and B(H) hysteresis loop, and coordinate message at every data point on the curve. 

·Multipoint cluster, can display B(H) magnetic hysteresis cycle cluster, B(H) magnetization curve, μa(H) permeability curve and Ps(B) damage curve, and it can display coordinate message at every data point on the curve. 

·B(H) magnetization curve and Ps(B) damage curve measured under different conditions can be combined on one drawing for comparative analysis. 

·Set up upper and lower limits according to μa, Ps, Bm, Br, Hc and Hm, etc. Qualify test result and determine through the color of data table. 

·Support various models of printers, test report accurately match printer sheet.

·Print preview function, can conveniently regulate the size and edge distance of test report.

·Test report can be directly printed, or generate JPG image file.

·JPG image file can be sent directly through E-mail, or saved into disk.

·Test reports contain complete curve diagrams, test results, test conditions and sample parameters. Both Chinese and English format can be adopted to facilitate adding user mark and enterprise name.

·Multiple unit systems optional to satisfy the application habits of different users.

Additional Accessories:

ATS-300M

Output power: 300VA, sine wave

Output Frequency: 50Hz, 60Hz

Frequency Error: Set value within ±0.05%

Output voltage: 0~10~50~80~100V(Effective value)

Output current: 0~30~300~3000~30000mA(Peak

value)

Voltage Distortion: superior to 0.5%

Voltage Stability: superior to 0.2%

Signal produce way: DDS digital

frequency Integration way

$12000

Epstein Frame

Conforms to National GB/T3655-2000, and can be

used together with MATS-2010M Hysteresisgraph.

Sample Size: 30mm×(280~300mm),

Max. Sample Mass: 1kg

$3,300